fix: broadcast the average SEI film overpotential with a size distribution - #5892
shaurya20335 wants to merge 4 commits into
Conversation
…ution With "SEI film resistance": "average", eta_sei is the x-averaged film drop on the current collector. With "particle size": "distribution" resolved through the electrode (SPMe, DFN, Newman-Tobias), eta_r lives on the particle-size domain with the electrode as its secondary domain, so adding eta_sei raised DomainError: children must have same or empty domains, not ['negative particle size'] and ['current collector']. Broadcast eta_sei onto the electrode in that case. Models that already built are unchanged. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
|
Looks correct, thanks. I checked it together with #5841 (SEI film heating) and #5875: every size-distribution model builds with no, average or distributed film, and with #5841 the Heads-up on #5818, which deprecates relying on options set from other options (the test suite turns that warning into an error): |
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…m-size-distribution # Conflicts: # CHANGELOG.md
|
Thanks @shaurya20335, this looks good to merge. I re-checked on current |
Description
With
"SEI film resistance": "average"and"particle size": "distribution", SPMe, DFN and Newman-Tobias fail to build:In
BaseKinetics, the average film dropeta_sei = -j_tot_av * L_sei_av * R_seilives on the current collector. When the size distribution is resolved through the electrode,eta_ris on the particle-size domain with the electrode as its secondary domain, soeta_r += eta_seicannot broadcast across the missing electrode level. MPM is not affected because itseta_ralready has the current collector as its secondary domain, and"distributed"is not affected because itseta_seiis on the electrode.eta_seiis now broadcast onto the electrode in that case. Nothing changes for models that already built: MPM and DFN without a distribution give bit-identical voltages with the average film.With the fix (OKane2022,
"SEI": "constant", 50 nm film, 5 A, voltage at 600 s):The average and distributed films differ by about 1 mV with a size distribution, as they do without one (1.5 mV for the DFN).
I found this while checking #5841 across model options.
Type of change
Bug fix, with an entry under
## Bug fixesin CHANGELOG.md.Important checks:
test_well_posed_psd_sei_film_resistance(unit, in the shared lithium-ion base tests) builds each model with a size distribution and both film options. It fails on main for SPMe, DFN and Newman-Tobias and passes with the fix.