75 changes: 75 additions & 0 deletions custom_components/checkwatt/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -2,6 +2,7 @@

from __future__ import annotations

import json
import logging
from datetime import UTC, date, datetime, timedelta
from zoneinfo import ZoneInfo
Expand All @@ -15,6 +16,7 @@

from .api import AuthenticationError, CheckwattApiClient
from .const import (
DIAG_UPDATE_INTERVAL,
DOMAIN,
ENERGY_UPDATE_INTERVAL,
LOGBOOK_UPDATE_INTERVAL,
Expand Down Expand Up @@ -50,6 +52,43 @@ def _select_spot_price(prices: list[dict], now_local: datetime) -> float | None:
return current


def _parse_diag_blob(blob: dict) -> dict:
"""Extract HA-relevant values from a connectionStatus Current.Blob.

Battery temperatures come from the inverter stats; with several inverters
the highest high and lowest low are reported, matching the EIB UI.
"""
temps_h: list[float] = []
temps_l: list[float] = []
inverter_stats = (blob.get("topics") or {}).get("ems/inverter_stat") or {}
for inverters in inverter_stats.values():
if not isinstance(inverters, list):
continue
for inv in inverters:
if not isinstance(inv, dict):
continue
if inv.get("temp_h") is not None:
temps_h.append(inv["temp_h"])
if inv.get("temp_l") is not None:
temps_l.append(inv["temp_l"])

default_route = blob.get("default_route") or []
if blob.get("hello_eth0"):
connection = "Network cable (LAN1)"
elif "ppp0" in default_route:
connection = "Mobile internet (4G)"
else:
connection = "No internet"

return {
"battery_temp_high_c": max(temps_h) if temps_h else None,
"battery_temp_low_c": min(temps_l) if temps_l else None,
"internet_connection": connection,
"cm10_uptime_s": blob.get("uptime_s"),
"default_route": default_route,
}


async def async_setup_entry(hass: HomeAssistant, entry: ConfigEntry) -> bool:
"""Set up CheckWatt from a config entry."""
# H2: dedicated session with explicit SSL verification.
Expand Down Expand Up @@ -121,6 +160,7 @@ def __init__(
self._last_price_update: datetime | None = None
self._last_energy_update: datetime | None = None
self._last_logbook_update: datetime | None = None
self._last_diag_update: datetime | None = None
self._last_news_update: datetime | None = None
self._last_news_ts: str | None = None

Expand Down Expand Up @@ -156,6 +196,12 @@ async def _async_update_data(self) -> dict:
if new_test_status is not None:
self._last_test_status = new_test_status

# Available power the battery can offer CheckWatt right now
# (the EIB "Available power" panel).
related_meters = {
m.get("Type"): m.get("PeakAcKw") for m in status.get("RelatedMeters") or []
}

data: dict = {
# Identity
"site_id": self._site_id,
Expand All @@ -172,6 +218,8 @@ async def _async_update_data(self) -> dict:
"operation_preference": status.get("OperationPreference"),
"fp_up_kw": status.get("FpUpInKw"),
"fp_down_kw": status.get("FpDownInKw"),
"available_charge_kw": related_meters.get("Charging"),
"available_discharge_kw": related_meters.get("Discharging"),
"test_info": test_info,
"logbook_raw": self._logbook_raw,
# Event signals — reset each cycle, set below if triggered.
Expand Down Expand Up @@ -201,6 +249,10 @@ async def _async_update_data(self) -> dict:
await self._update_logbook(data)
self._last_logbook_update = now

if self._due(self._last_diag_update, DIAG_UPDATE_INTERVAL):
await self._update_diagnostics(data)
self._last_diag_update = now

if self._due(self._last_news_update, NEWS_UPDATE_INTERVAL):
await self._update_news(data)
self._last_news_update = now
Expand Down Expand Up @@ -281,6 +333,11 @@ def _slow_data(self) -> dict:
"total_export_kwh": None,
"total_charge_kwh": None,
"total_discharge_kwh": None,
"battery_temp_high_c": None,
"battery_temp_low_c": None,
"internet_connection": None,
"cm10_uptime_s": None,
"default_route": None,
}
# Note: event signals (cm10_status_changed, new_logbook_entries) are
# intentionally NOT carried over — they must only fire once per occurrence.
Expand All @@ -296,6 +353,11 @@ def _slow_data(self) -> dict:
"total_export_kwh",
"total_charge_kwh",
"total_discharge_kwh",
"battery_temp_high_c",
"battery_temp_low_c",
"internet_connection",
"cm10_uptime_s",
"default_route",
)
}

Expand Down Expand Up @@ -369,6 +431,19 @@ async def _update_logbook(self, data: dict) -> None:
except Exception as err:
_LOGGER.warning("Logbook update failed (%s): %s", type(err).__name__, err)

async def _update_diagnostics(self, data: dict) -> None:
"""Fetch CM10 diagnostics: battery temperatures and internet connection."""
try:
resp = await self._client.get_connection_status(self._site_id)
blob_raw = (resp.get("Current") or {}).get("Blob")
if not blob_raw:
return
blob = json.loads(blob_raw)
if isinstance(blob, dict):
data.update(_parse_diag_blob(blob))
except Exception as err:
_LOGGER.warning("Diagnostics update failed (%s): %s", type(err).__name__, err)

async def _update_news(self, data: dict) -> None:
"""Fetch news and detect items published since the last check."""
try:
Expand Down
17 changes: 17 additions & 0 deletions custom_components/checkwatt/api.py
Original file line number Diff line number Diff line change
Expand Up @@ -225,6 +225,23 @@ async def get_news(self) -> list:
except (ClientResponseError, ClientError) as err:
raise ConnectionError(f"News request failed: {type(err).__name__}") from err

async def get_connection_status(self, site_id: int) -> dict:
"""Fetch CM10 diagnostics: connectivity, uptime and inverter temperatures.

New endpoint 2026-09, backs the EIB "Internet connection" and
"Battery temperature" panels. The interesting data lives in
Current.Blob, a JSON-encoded string.
"""
now = datetime.now(UTC)
fmt = "%Y-%m-%dT%H:%M:%S.000Z"
return await self._get(
f"/diag/{site_id}/connectionStatus",
params={
"from": (now - timedelta(minutes=5)).strftime(fmt),
"to": now.strftime(fmt),
},
)

async def get_energy_totals(self, meter_ids: list[int]) -> dict:
"""Fetch all-time yearly-grouped totals for the given meter IDs."""
from datetime import date
Expand Down
1 change: 1 addition & 0 deletions custom_components/checkwatt/const.py
Original file line number Diff line number Diff line change
Expand Up @@ -12,4 +12,5 @@
PRICE_UPDATE_INTERVAL = timedelta(minutes=60)
ENERGY_UPDATE_INTERVAL = timedelta(minutes=15)
LOGBOOK_UPDATE_INTERVAL = timedelta(minutes=30)
DIAG_UPDATE_INTERVAL = timedelta(minutes=5)
NEWS_UPDATE_INTERVAL = timedelta(hours=4)
2 changes: 1 addition & 1 deletion custom_components/checkwatt/manifest.json
Original file line number Diff line number Diff line change
@@ -1,7 +1,7 @@
{
"domain": "checkwatt",
"name": "CheckWatt",
"version": "1.4.3",
"version": "1.5.0",
"documentation": "https://github.com/andreasthell/ha-cw",
"issue_tracker": "https://github.com/andreasthell/ha-cw/issues",
"codeowners": ["@andreasthell"],
Expand Down
50 changes: 50 additions & 0 deletions custom_components/checkwatt/sensor.py
Original file line number Diff line number Diff line change
Expand Up @@ -18,6 +18,7 @@
PERCENTAGE,
UnitOfEnergy,
UnitOfPower,
UnitOfTemperature,
)
from homeassistant.core import HomeAssistant
from homeassistant.helpers.device_registry import DeviceInfo
Expand Down Expand Up @@ -164,6 +165,44 @@ def _parse_dt(value: str | None) -> datetime | None:
suggested_display_precision=0,
value_fn=lambda d: d.get("battery_soc_pct"),
),
# ---- Available power (EIB "Available power" panel) ----------------------
CheckwattSensorDescription(
key="available_charge_kw",
translation_key="available_charge_power",
device_class=SensorDeviceClass.POWER,
state_class=SensorStateClass.MEASUREMENT,
native_unit_of_measurement=UnitOfPower.KILO_WATT,
suggested_display_precision=1,
value_fn=lambda d: d.get("available_charge_kw"),
),
CheckwattSensorDescription(
key="available_discharge_kw",
translation_key="available_discharge_power",
device_class=SensorDeviceClass.POWER,
state_class=SensorStateClass.MEASUREMENT,
native_unit_of_measurement=UnitOfPower.KILO_WATT,
suggested_display_precision=1,
value_fn=lambda d: d.get("available_discharge_kw"),
),
# ---- Battery temperature ------------------------------------------------
CheckwattSensorDescription(
key="battery_temp_high_c",
translation_key="battery_temp_high",
device_class=SensorDeviceClass.TEMPERATURE,
state_class=SensorStateClass.MEASUREMENT,
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
suggested_display_precision=1,
value_fn=lambda d: d.get("battery_temp_high_c"),
),
CheckwattSensorDescription(
key="battery_temp_low_c",
translation_key="battery_temp_low",
device_class=SensorDeviceClass.TEMPERATURE,
state_class=SensorStateClass.MEASUREMENT,
native_unit_of_measurement=UnitOfTemperature.CELSIUS,
suggested_display_precision=1,
value_fn=lambda d: d.get("battery_temp_low_c"),
),
# ---- Revenue ------------------------------------------------------------
CheckwattSensorDescription(
key="today_revenue_sek",
Expand Down Expand Up @@ -293,6 +332,12 @@ def _parse_dt(value: str | None) -> datetime | None:
icon="mdi:notebook-outline",
value_fn=lambda d: _logbook_state(d.get("logbook_raw")),
),
CheckwattSensorDescription(
key="internet_connection",
translation_key="internet_connection",
icon="mdi:lan",
value_fn=lambda d: d.get("internet_connection"),
),
CheckwattSensorDescription(
key="firmware_version",
translation_key="firmware_version",
Expand Down Expand Up @@ -366,4 +411,9 @@ def extra_state_attributes(self) -> dict | None:
for e in entries[:5]
]
return {"recent_entries": recent}
if key == "internet_connection":
return {
"uptime_s": self.coordinator.data.get("cm10_uptime_s"),
"default_route": self.coordinator.data.get("default_route"),
}
return None
5 changes: 5 additions & 0 deletions custom_components/checkwatt/strings.json
Original file line number Diff line number Diff line change
Expand Up @@ -44,6 +44,11 @@
"total_grid_export": {"name": "Total Grid Export"},
"total_battery_charge": {"name": "Total Battery Charge"},
"total_battery_discharge": {"name": "Total Battery Discharge"},
"available_charge_power": {"name": "Available Charge Power"},
"available_discharge_power": {"name": "Available Discharge Power"},
"battery_temp_high": {"name": "Battery Temperature High"},
"battery_temp_low": {"name": "Battery Temperature Low"},
"internet_connection": {"name": "Internet Connection"},
"cm10_status": {"name": "CM10 Status"},
"last_seen_cm10": {"name": "CM10 Last Seen"},
"last_seen_inverter": {"name": "Inverter Last Seen"},
Expand Down
5 changes: 5 additions & 0 deletions custom_components/checkwatt/translations/en.json
Original file line number Diff line number Diff line change
Expand Up @@ -44,6 +44,11 @@
"total_grid_export": {"name": "Total Grid Export"},
"total_battery_charge": {"name": "Total Battery Charge"},
"total_battery_discharge": {"name": "Total Battery Discharge"},
"available_charge_power": {"name": "Available Charge Power"},
"available_discharge_power": {"name": "Available Discharge Power"},
"battery_temp_high": {"name": "Battery Temperature High"},
"battery_temp_low": {"name": "Battery Temperature Low"},
"internet_connection": {"name": "Internet Connection"},
"cm10_status": {"name": "CM10 Status"},
"last_seen_cm10": {"name": "CM10 Last Seen"},
"last_seen_inverter": {"name": "Inverter Last Seen"},
Expand Down
5 changes: 5 additions & 0 deletions custom_components/checkwatt/translations/sv.json
Original file line number Diff line number Diff line change
Expand Up @@ -44,6 +44,11 @@
"total_grid_export": {"name": "Total nätexport"},
"total_battery_charge": {"name": "Total batteriladdning"},
"total_battery_discharge": {"name": "Total batteriurladdning"},
"available_charge_power": {"name": "Tillgänglig laddeffekt"},
"available_discharge_power": {"name": "Tillgänglig urladdningseffekt"},
"battery_temp_high": {"name": "Batteritemperatur högsta"},
"battery_temp_low": {"name": "Batteritemperatur lägsta"},
"internet_connection": {"name": "Internetanslutning"},
"cm10_status": {"name": "CM10 Status"},
"last_seen_cm10": {"name": "CM10 senast sedd"},
"last_seen_inverter": {"name": "Växelriktare senast sedd"},
Expand Down
73 changes: 73 additions & 0 deletions docs/api.md
Original file line number Diff line number Diff line change
Expand Up @@ -825,6 +825,78 @@ Returns pending EMS configuration changes. Response is an array of service strin

---

## Diagnostics

### Get connection status (new 2026-09)

```
GET /diag/{site_id}/connectionStatus?from={iso_utc}&to={iso_utc}
Authorization: Bearer {jwt_token}
```

Backs the EIB "Internet connection" and "Battery temperature" panels. The web
app queries a 5-minute window ending now (ISO 8601 UTC with milliseconds, e.g.
`2026-09-16T09:20:46.097Z`).

**Response 200:**
```json
{
"SiteId": 12345,
"From": "2026-09-16T09:20:46.097Z",
"To": "2026-09-16T09:25:46.097Z",
"Current": {"Timestamp": "2026-09-16T08:13:35Z", "Blob": "{...json string...}"},
"History": []
}
```

`Current.Blob` is a **JSON-encoded string** with CM10 diagnostics:

```json
{
"eth": {"eth0": {"rx_packets": 4527, "carrier_changes": 0}, "eth1": {}, "win_s": 4197},
"topics": {
"ems/inverter_stat": {
"goodwe": [
{
"id": "192.168.5.128",
"soc": 85.0,
"model": "GW10KN-ET",
"serial": "...",
"fw_ver": "master:13-slave:13 /arm:33",
"temp_h": 36.4,
"temp_l": 20.8,
"pv_power": 0.0,
"battery_power": -12.0,
"set_point": 0.0
}
]
},
"ems/datastream_energyPv": 0.0,
"ems/datastream_energyImport": 186.0,
"ems/datastream_energyDischarge": -12.0
},
"screens": ["15814.sender", "15811.goodwe", "..."],
"arp_eth1": [{"ip": "192.168.5.128", "mac": "...", "state": ["REACHABLE"]}],
"uptime_s": 1114187,
"linux_ips": [{"ip": "...", "iface": "eth0"}],
"hello_eth0": true,
"modem_stat": {"ts": "2026-09-16 04:05:04", "status": "modem"},
"default_route": ["ppp0", "eth0"]
}
```

Key fields:
- `topics."ems/inverter_stat".{vendor}[].temp_h` / `temp_l` – battery temperature highest/lowest (°C)
- `hello_eth0` – LAN1 internet check succeeded (EIB shows "Primary – Network cable (LAN1): Connected")
- `default_route` – active route interfaces (`eth0` = LAN1, `ppp0` = 4G modem)
- `uptime_s` – CM10 uptime in seconds
- `eth1` / `arp_eth1` – the inverter-facing LAN port

The "Available power" panel (Can charge / Can discharge) comes from
`RelatedMeters[].PeakAcKw` in `/site/Statuses`, not from this endpoint.

---

## Misc

### Get energy providers list
Expand All @@ -849,6 +921,7 @@ No auth required. Returns all energy retailers across SE/NO/DK/FI with Id and Di
| Monthly revenue | 15 min | `/revenue/{siteId}` |
| Spot price | 60 min (or at :00 when tomorrow's prices arrive ~13:00) | `/ems/spotprice` |
| Site status / CM10 seen | 5 min | `/site/Statuses` |
| Diagnostics (battery temp, connectivity) | 5 min | `/diag/{siteId}/connectionStatus` |
| Site details / tariff | On setup + daily | `/site/{siteId}`, `/Tariff/{id}` |

### Token lifecycle
Expand Down
Loading
Loading