After designing a harness with WireViz and setting show_equiv to true for my wires, I noticed the conversion from 20 AWG to mm² was not correct. 20 AWG should be 0.5mm², but WireViz converted it to 0.75mm².
I took a look at wv_helper.py and noticed that awg_equiv_table seems to have incorrect values for 21AWG, 20AWG, & 18AWG. That's according to this table I found after a quick Google search: https://lexproducts.com/technical/wire-conversion. Other tables I looked at seem to agree as well though.
After designing a harness with WireViz and setting
show_equivtotruefor my wires, I noticed the conversion from 20 AWG to mm² was not correct. 20 AWG should be 0.5mm², but WireViz converted it to 0.75mm².I took a look at