[iOS] HRV is not recorded and doesn't calibrate #2335

Open

Description

@rodrigosa7

NOOP version

11.8

Platform

iOS

OS version

iOS 27

WHOOP strap / Oura ring model

WHOOP 4.0

Where the data is coming from

Live Bluetooth (WHOOP strap connected)

Test Centre profile

Not a test-mode bug

What happens

I just got my Whoop yesterday, and went to sleep. When I woke up today the app says that no HRV was recorded even though I slept with it and even have the Sleep tab filled with data. I didn't have the test centre enabled but exported a log for this.

Image Image

What you expected instead

I was expecting to have HRV measure so the app starts calibrating

Steps to reproduce

  1. Strap the band.
  2. Go to sleep.
  3. No HRV recorded in the morning.

Strap log

report.txt

Before you submit

  • I attached my exported NOOP .zip (not a screenshot of the Live screen). If my bug is a clearly reproducible UI issue I described exactly how to see it instead.
  • I attached or pasted a strap log above — or my bug is a clearly reproducible UI issue that doesn't need one (e.g. a typo, a button that does nothing) and I've described exactly how to see it.
  • I checked the Troubleshooting guide — especially "history syncs but no data" (most often the strap isn't banking history to flash; charge it to 100% and reconnect).
  • I checked the FAQ and — if I'm on a WHOOP 5.0 / MG — the 5.0/MG status page, or — if I'm on an Oura ring — the Oura ring support table, and this isn't an already-known limit (e.g. SpO₂, recovery/sleep on the 5/MG, or no Recovery / HRV on a ring-only day).
  • I've left out anything personal (strap serial, account email, raw export).

Activity

  1. ryanbr commented on Sep 19, 2026

    @ryanbr
    Owner

    Thanks @rodrigosa7, this log is a clean reproduction of #1118, which is currently labelled not reproducible. It is not a display bug.

    Your night stages fine (totalSleepMin=446 eff=0.95) and the beats arrive: 45,897 of them, meanNN=1125ms. But coverage=1.83, meaning the night banks 1.83 seconds of beat time per second of wall clock where about 1.0 is possible. That verdict is crossSecondOverCount, and SleepStager.sessionAvgHRV refuses such a night outright rather than publish an RMSSD built on doubled beats. That one gate feeds the daily row, the card and the baseline, which is why HRV is blank and why calibration never advances. One cause, both symptoms.

    Two cheap explanations are ruled out by your own data:

    rr dupPairs n=16805 same=342 tick=757 other=15706 medPPT=1049
    

    Those are value ratios. tick is the 1024/1000 unit-mismatch signature (4%), same is identical rows re-inserted (2%). 94% are genuinely different beats, median 4.9% apart, which is ordinary variation.

    The useful part is that each offload batch looks correct on its own:

    rr emit path=historical offered=396 inserted=396 secs=383 sumRr=475s span=504s ratio=0.94
    rr deliveries secs[1/2/3/4+]=5600/18844/101/0
    

    Every batch sits near ratio 1.0, yet the night totals 1.83, and 18,844 of your 24,545 seconds carry two delivery starts rather than one. So the doubling appears in the accumulation, not in any single record. That is new for #1118 and narrows it a long way.

    Nothing is wrong with your strap or your setup, and there is no setting to change. Tracking it on #1118.

    If you are willing: a Test Centre capture (Connection and Sync) over a night would carry the pre-storage census, which should show whether the second delivery enters at ingest or at insert. No rush, and your ordinary use is unaffected apart from the blank.

  2. rodrigosa7 commented on Sep 19, 2026

    @rodrigosa7
    Author

    Thanks for the explanation @ryanbr !
    I'll activate the Connection and Sync logs, and tomorrow morning after I wake up will upload it here or in #1118 if you prefer!

    If you need anything else from my side just let me know!
    Cheers

  3. rodrigosa7 commented on Sep 21, 2026

    @rodrigosa7
    Author

    Hey again @ryanbr
    Just want you to know that the issue persists and I left the logs on the other issue #1118
    It keeps saying that didn’t record HRV :/

  4. mwld commented on Sep 23, 2026

    @mwld

    FYI: I had the same issues with no HRV being measured on a Whoop 5.0/MG with versions 11.5.0 and 11.7.0. I reverted back to 11.1.0 where it works fine.

  5. rodrigosa7 commented on Sep 23, 2026

    @rodrigosa7
    Author

    Can confirm that downgrading to 11.1 works thanks @mwld

  6. sartoiu commented on Sep 25, 2026

    @sartoiu

    Still no HRV in new version, thanks downgrading to 11.1 works just fine

  7. mwld commented on Oct 14, 2026

    @mwld

    Got this bug fixed with #2441 in 12.0.0 @rodrigosa7 ?