@aricciv

I found that some of the values from the NIST database are outdated. In particular, the A coefficient for the 40Ca+ ion D5/2 (729 nm) transition is pretty off. The value from NIST is a theoretical value of 1.3 s^-1 , whereas more recent measurements (i.e. https://journals.aps.org/pra/abstract/10.1103/PhysRevA.62.032503) give 0.86 s-1. Dipole transitions have less discrepancies, but are still outdated.