ESP32 (LilyGO T-POE-PRO) Modbus Gateway between SolarEdge/RTU and EM24/TCP

This is a gateway to connect a SolarEdge inverter to your own energy meter.

SolarEdge can only communicate to a specific set of energy meters, sold by SolarEdge. These meters are expensive and it adds clutter to your electricity cabinet when you already have an energy meter.

This projects aims to reuse your own energy meter. This projects mimics a WattNode meter, which is compatible with SolarEdge and well documented. It retrieves the energy and power values from a Carlo Gavazzi EM24 energy meter, which it then translates to the WattNode definitions.

It not only converts the different energy meter definitions, it also converts the physical layer between Modbus-RTU and Modbus-TCP.

The SolarEdge inverter connects to the LilyGO ETH-POE-PRO through Modbus-RTU over RS-485. The LilyGO-POE-PRO connects to a Carlo Gavazzi EM24 through Modbus-TCP. The gateway translates the registers and values as needed.

1 PlatformIO Quick Start

  1. Install Visual Studio Code and Python
  2. Search for the PlatformIO plugin in the VisualStudioCode extension and install it.
  3. After the installation is complete, you need to restart VisualStudioCode
  4. After restarting VisualStudioCode, select File in the upper left corner of VisualStudioCode -> Open Folder -> select the LilyGO-ModbusGateway directory
  5. Wait for the installation of third-party dependent libraries to complete
  6. Click the (✔) symbol in the lower left corner to compile
  7. Connect the board to the computer USB (If there is no onboard downloader, USB2TTL must be connected)
  8. Click (→) to upload firmware
  9. Click (plug symbol) to monitor serial output

Source layout

src/
  main.cpp                 Board, networking, HTTP host and OTA
  utilities.h              Board pin definitions
  application/plugin.h     Device-independent plugin contract
  modbus/                  Shared schema, codec, storage and transport code
  devices/                 Reusable manufacturer-defined schemas and factories
  plugin/                  Complete implementation selected by this branch
    plugin.cpp             Device ownership, startup, polling and web handlers
    devices/               Plugin-specific schemas (such as Optimizer)
    convert_*.h / .cpp     Device-specific conversion

master implements the EM24-to-WattNode gateway. optimize-battery-usage implements the gateway with additional battery optimization. Both are complete plugins; neither implementation is hardcoded in the host or test runner.

Creating another gateway

  1. Create a branch from master.
  2. Replace src/plugin/ with your device selection, transport configuration and conversion. Reuse schemas from src/devices/; keep custom application schemas in the plugin.
  3. Implement the three functions declared in src/application/plugin.h: setup(WebServer&), loop(unsigned long) and appendRootLinks(String&).
  4. Replace the matching tests and source list in modbus_regression/plugin/.
  5. Run the native tests and firmware build.

The host calls setup after networking is ready and before the HTTP server starts. A plugin registers its own routes, starts its transports and initializes its timers. loop performs its own polling and conversion and returns true when the host should yield. The root page includes plugin-supplied menu links; /info and the HTTP fallback belong to the host.

There is exactly one statically linked plugin, compiled automatically from src/plugin/; no activation macro or runtime registration is required. A plugin may use entirely different devices or transports without changing main.cpp, platformio.ini or src/modbus/. Configure installation-specific addresses and IDs through your plugin and existing local secrets.ini build flags.

Shared host/infrastructure improvements can be made on master and merged into other branches. Concrete plugin implementations may intentionally diverge.

Validation

python3 modbus_regression/tests/run.py --project-src src
pio run -e T-ETH-POE-PRO

The shared native runner delegates to modbus_regression/plugin/run.py. That implementation-specific runner selects devices and compiles production conversion code with native transport-owner substitutes. Register definitions, word order, scaling and default values remain subject to the same compile-time checks.

Shared device catalog

src/devices/ contains Alfen, SolarEdge, WattNode and EM24_E1 on both branches. Plugins include the devices they need, for example #include "devices/alfen.h". The catalog provides schemas and factories; it opens no connections, registers no endpoints and schedules no polling. The plugin creates the actual instances. The application-defined Optimizer schema remains under src/plugin/devices/.

Shared catalog tests live in modbus_regression/devices/ and run on every branch, including for devices that its plugin does not use. Adding a reusable device does not require a change to the host or existing plugins.

Modbus infrastructure behavior

Client data notifications are consumed with consumeUpdated() before conversion. An update arriving during conversion remains pending for a subsequent pass. Use DataAccess for device values; client/server storage is private.

Each client keeps up to 32 pending requests in fixed storage. A full context table rejects new requests until a completion or error releases a slot. Tokens are numeric IDs, so callbacks do not depend on the host pointer width. A client exclusively owns its transport's data/error callback pair. Stop/drain the transport before destroying its client; callbacks are detached during destruction.

Servers bind callbacks to their own instance. The same schema may be used by multiple endpoints; an occupied transport/server-ID/function combination is rejected and registered() reports false. Stop request processing before destroying a server; its registered workers are then removed.

Statistics use atomic counters and serialized sampling. The log has a fixed 200-entry ring, synchronized reads/writes, and nonblocking wall-clock timestamps with an uptime fallback before the clock is synchronized. Strings still allocate their own contents.

Schemas retain metadata.valid and also expose the first metadata.error as a SchemaError. Device rejects invalid schemas at compile time, including unrepresentable addresses, offsets, lengths and invalid field properties.

Client and Server expose getLog(), getStatistics() and logMessage() directly. These methods use diagnostics' own synchronization without taking the register lock. DataAccess exclusively provides register access.

HTTP handlers collect register responses inside a short DataAccess scope, release the guard, then send the response. Strategy handlers also release the guard before writing preferences to flash. The response describes the register state captured when the strategy was set.

Reading the Modbus code

Start with a device header in src/devices/ to see a concrete layout, then read the public API of Device, Client or Server. The schema builder can be read after those interfaces: its nested lambdas implement the compile-time layout, rather than the runtime request flow.

File Responsibility Useful entry points
register_schema.h Declare and validate immutable register layouts field, block, makeDeviceSchema
register_codec.h Convert raw values to and from Modbus words decodeTyped, encodeTyped, loadBits, storeBits
device.h Store words and validate address ranges get, set, readHoldingRegisters, writeHoldingRegisters
data_access.h Hold an owner's register lock for one scope constructor and destructor
client.h Schedule TCP reads and publish validated replies submit, handleData, validResponse
server.h Validate protocol requests and serve cached words processRequest, validateRequest, readRegisters, writeRegisters
diagnostics.h Synchronize counters and the log ring Statistics, Log
device_diagnostics.h Format register values and layout descriptions formatRegisterValue, formatDeviceValues, printDeviceDescription
definitions.h Collect the shared interfaces in one include includes only

Schema denotes a device layout type. A register template argument denotes an enum ID known at compile time; value_type<Register> derives its C++ value type from that layout. typename and the dependent-call template keyword are C++ syntax qualifiers, not extra runtime operations. Typed access returns raw native values; engineering scaling is applied explicitly by conversion or diagnostics.

The two runtime flows are:

  • Incoming request: server validation, register read/write under DataAccess, response.
  • Outgoing read: client range validation, request reservation, transport enqueue, callback validation, register publication under DataAccess, update notification.

The request-table mutex protects tokens and slots; DataAccess protects register words. Neither lock is held while enqueueing a transport request. Logs and statistics own their separate synchronization.