This custom component integrates MijnTed devices with Home Assistant, allowing you to monitor your energy usage and other related data within your smart home setup.

Documentation

This README covers installation, configuration, and everyday usage. Detailed references live in doc/:

Guide What it covers
Sensors and buttons Values, attributes, missing-data behavior, statistics, and the reset button
Month transitions API lag, month lifecycle, baseline locking, and late corrections
API and authentication Endpoints, client methods, response formats, and token rotation
Reporting issues Diagnostic information and a bug-report template
Development Environment setup, tests, Home Assistant verification, and agent tooling

Installation

  1. Download mijnted.zip from the desired GitHub release.
  2. Extract its contents into your Home Assistant's custom_components/mijnted directory. The ZIP contains manifest.json and the integration files directly at its root.
  3. Restart Home Assistant.
  4. Go to Settings > Devices & services > Integrations.
  5. Click the "+ ADD INTEGRATION" button and search for "MijnTed".
  6. Follow the configuration steps.

Use the attached integration ZIP, rather than GitHub's automatic Source code archives: the release ZIP contains the exact installed version. Repository checkouts intentionally report 0.0.0-dev.0. Older releases without a mijnted.zip asset can still be installed manually by copying their tagged custom_components/mijnted directory.

Installation via HACS

  1. Ensure that HACS is installed.
  2. In Home Assistant, go to HACS > Integrations.
  3. Click on the three dots in the top right corner and select "Custom repositories".
  4. Enter the following information:
    • URL: https://github.com/codezorz/home-assistant-mijnted
    • Category: Integration
  5. Click "Add".
  6. Search for "MijnTed" in HACS and install it.
  7. Restart Home Assistant.
  8. Go to Settings > Devices & services > Integrations.
  9. Click the "+ ADD INTEGRATION" button and search for "MijnTed".
  10. Follow the configuration steps.

HACS installs the versioned mijnted.zip release asset. Stable releases are the normal choice; enable prerelease versions in HACS to test numbered betas such as v1.0.26-beta.1. Direct downloads of main are hidden in HACS. Historical releases without the ZIP asset are available through manual installation.

Integration icon

Home Assistant 2026.3 and newer display the bundled MijnTed icon from custom_components/mijnted/brand/. The images are included in the release ZIP and installed by HACS; no separate branding configuration is needed. Older Home Assistant versions do not support these local brand images.

Configuration

To set up the MijnTed integration, you'll need:

  1. Your MijnTed client ID
  2. Your MijnTed username (email address)
  3. Your MijnTed password

You can also choose a device name, such as Home or Office. Home Assistant uses this name as the prefix for the integration's entity names. The name and polling interval can be changed later from the integration's configuration options.

Obtaining Your Client ID

The Client ID can be extracted from a browser network request:

  1. Log in to the MijnTed website
  2. Open your browser's developer console (F12)
  3. Go to the Network tab
  4. Look for a POST request to https://mytedprod.b2clogin.com/mytedprod.onmicrosoft.com/b2c_1_user/oauth2/v2.0/token
  5. Click on the request and go to the "Payload" or "Request" tab (depending on your browser)
  6. In the form parameters, you'll find:
    • Client ID: The value of the client_id parameter (typically a UUID format)

The request will look something like this:

POST https://mytedprod.b2clogin.com/mytedprod.onmicrosoft.com/b2c_1_user/oauth2/v2.0/token

Form Data:
- client_id: xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx
- refresh_token: ...
- grant_type: refresh_token
- scope: openid offline_access ...

Note: The client ID is typically a UUID format (e.g., xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx).

Polling Interval (Optional):

  • Default: 3600 seconds (1 hour)
  • Range: 3600-86400 seconds (1 hour to 24 hours)
  • You can configure this during setup or leave it at the default
  • To change it later, open the integration's options/configure dialog in Settings > Devices & services. Saving the interval reloads the integration.

During setup, enter your client ID, username, and password. The integration handles OAuth 2.0 and retains credentials and tokens in the Home Assistant config entry for automatic reauthentication. See the authentication reference for details.

Usage

Once configured, the integration will create several sensors in Home Assistant:

Detailed references: sensor catalog, month-switch timeline, and API/authentication.

  • Monthly usage - Current calendar month's energy usage, calculated from start/end readings with annual-reset handling in January. Attributes include start_date, end_date, days, and month_id. Use the Last update sensor to see the date through which API readings are available.
  • Last year monthly usage - Last year's monthly usage for the corresponding month (prefers API-provided value from previous year's data)
  • Average monthly usage - Average usage extracted from historical monthly usage data
  • Last year average monthly usage - Last year's average monthly usage for the corresponding month (prefers API-provided value from previous year's data)
  • Total usage - Sum of all device readings (cumulative filter status, accumulating counter). Attributes expose aligned month payloads for current and history, including month status (OPEN, COMPLETE_READINGS, FINALIZED). Automatically injects historical data for proper history graphs.
  • Last update - Date for which device readings are currently available from the API (often 1-2 days behind)
  • Last successful sync - Timestamp of the most recent returned refresh payload; some individual endpoints can have failed during that refresh
  • Active model - The active model identifier (e.g., "F71")
  • Delivery type - Available delivery types for your residential unit
  • Residential unit - Detailed information about your residential unit
  • Unit of measures - Unit of measurement information
  • Latest available insight - Month with the last available insight data including average. Displays the month name only (e.g. "January 2026"). Attributes include month_id, usage_unit, has_average.
  • Device Sensors - Individual sensors for each device/room (dynamically created based on your setup, named by room when available)
  • Reset statistics - Button to reset statistics tracking and trigger re-injection of historical data. See reset behavior for what it clears.

Usage sensors request zero decimal places for display; underlying values retain their precision.

History and Statistics

With recorder enabled, usage sensors import historical long-term statistics. This does not backfill ordinary sensor state history. Total usage uses TOTAL_INCREASING; other usage sensors use TOTAL. Average statistics are state-only: use the Statistics state view for the two average entities.

Late month corrections can trigger reinjection. The reset button rebuilds the integration cache and injection tracking; it does not delete recorder data. See statistics behavior for the full contract and month-switch behavior for boundary cases.

You can use these sensors in your automations, scripts, and dashboards to monitor and analyze your energy consumption. The sensors include additional attributes with detailed information that can be accessed in templates and automations.

API

MijntedApi handles data endpoints and MijntedAuth manages tokens and credential-based rotation. The endpoint reference owns the method mapping, request/response examples, and retry details.

Troubleshooting

If you encounter issues:

  1. Check that your MijnTed client ID and login credentials are correct and that you can log in on the MijnTed website.
  2. Ensure your internet connection is stable.
  3. Verify that the MijnTed API is accessible.
  4. Refresh-token rotation is automatic. If it fails and Home Assistant requests reauthentication, complete that flow with your client ID, username, and password; you do not need to paste a refresh token manually.
  5. If readings look stale, compare Last update with Last successful sync. MijnTed readings often lag the calendar date; a recent sync can also contain partial endpoint failures. Check logs and the sensor edge cases.

For more detailed error messages, enable debug logging for the MijnTed component in your Home Assistant configuration by adding the following to your configuration.yaml:

logger:
  default: info
  logs:
    custom_components.mijnted: debug

Reporting issues

When opening a GitHub issue, include reproducible steps, expected vs actual behavior, logs, and environment details.

  • See issue reporting for a full checklist and copy/paste bug report template.
  • Use the default GitHub issue forms (Bug report, Feature request, Question) to start with the right structure.
  • For security vulnerabilities, follow the private reporting policy instead of opening a public issue.

Contributing

Contributions are welcome! Please feel free to submit a Pull Request.

Start with the development guide for local setup, tests, CI, Home Assistant verification, and agent tooling. AGENTS.md maps implementation instructions; CLAUDE.md is the Claude entry point.

About

Home Assistant custom integration for MijnTed energy monitoring devices in the Netherlands

Topics

Resources

Security policy

Stars

4 stars

Watchers

1 watching

Forks

Releases

Used by

Contributors

Languages